Auto Titrator Orion Star Model T910

Orion Star T910 pH titrator without electrode. 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies

Burette Functions Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc Functions Available Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV) ±0.2 mV Accuracy (pH) ±0.002pH
Accuracy (Temperature) ±0.2 °C Alarm Output Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option Yes, adjustable Blank Options Fixed value or variable value using titration
Burette Sizes 10 mL, 20 mL (included) or 50 mL Calibration pH and temperature
Calibration Points (pH) 1 to 5 Certifications/Compliance CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels 1 Cycles Per Titration Run 1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details Data log export as CSV or PDF file, short or long format Data Points 100 data sets each: sample titration, titrant standardization, calibration and direct measure
Display Type 5.7” color capacitive touchscreen, 640 x 480 resolution Type Acid/base titrator
Equivalence Points 1 to 2 For Use With (Application) Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Inputs BNC (pH electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe) IP Rating IP-51
Languages Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish Material ABS Plastic
Memory Non-volatile memory preserves data logs and settings Methods Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model Orion Star T910 Outputs 3 USB ports for printer, USB flash drive and computer software connections
Precision 0.5% RSD, dependent on environment and handling conditions Preset Endpoints 1 to 3
Probe Type pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe Range (mV) -2000.0 to +2000.0 mV
Range (pH) -2 to 20 Relative Humidity Range 5 to 85%, non-condensing
Resolution Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range) Resolution (mV) 0.1 mV
Resolution (pH) 0.001, 0.01, 0.1 (user selectable) Resolution (Temperature) 0.1 °C
Sample ID Auto-incremental, manual or off Stirrer Probe Speeds 5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating 41°F to 104°F Temperature (Metric) Operating 5°C to 40°C
Temperature Probe Calibration Optional 1 point offset calibration Temperature Range (Metric) -5.0°C to +100.0°C
Temperature Selection Manual or automatic Time and Date Yes, with nonvolatile battery backup
Titrant Determination Standardization titration or manual concentration input Titration Process Control Routine, quick, careful or user defined
Titration Setup Wizard Yes, using Start a New Titration workflow Titration Technique Equivalence point or preset endpoint
Titration Types Direct or back titration Updateable Firmware Yes, using USB flash drive
Warranty 1 year replacement warranty Dimensions (L x W x H) 10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical Requirements 100-240V, 50/60 Hz
  • Offers easy-to-use navigation from setup to live titration analysis to data transfer
  • Showcase titrations, onscreen instructions and help menus on a large color graphic touchscreen display.
  • Create and save up to ten user-defined methods
  • Save up to 100 titration data sets with date/time stamp
  • Facilitate data transfer to printer, computer, or USB drive
  • Bottle holder helps secure titrant to prevent spills
  • Color-coded tubing and connectors simplify tubing installation and maintenance
  • Stirrer probe provides consistent sample mixing, helps prevent damage to electrodes and is easy to rinse between samples.

Additional information